Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
J Feline Med Surg ; 26(4): 1098612X241232546, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38661475

RESUMO

OBJECTIVES: The aim of the present study was to retrospectively assess remission rates and survival in diabetic cats managed using a moderate-intensity, low-cost protocol of home blood glucose measurements and insulin adjustment by clients of a cat-only practice, and to determine if predictors of remission, relapse or survival could be identified. METHODS: The records of a cat-only practice were used to identify 174 cats with newly diagnosed diabetes managed using only pre-insulin home blood glucose measurements for insulin dose adjustments based on a protocol provided to clients aimed at maintaining pre-insulin blood glucose in the range of 6.5-11.9 mmol/l (117-214 mg/dl). Cats were excluded for the following reasons: insufficient follow-up in the records; a lack of owner compliance was recorded; they were receiving ongoing corticosteroids for the management of other conditions; they were euthanased at the time of diagnosis; or they were diagnosed with acromegaly or hyperadrenocorticism. RESULTS: Using only pre-insulin blood glucose measurements at home to adjust the insulin dose to maintain glucose in the range of 6.5-11.9 mmol/l, 47% of cats achieved remission, but 40% of those cats relapsed. A minority (16%) of cats were hospitalised for hypoglycaemia. The survival time was significantly longer in cats in remission and Burmese cats. CONCLUSIONS AND RELEVANCE: The cost and time burden of treating diabetic cats may cause some clients to choose euthanasia over treatment. While the highest rates of diabetic remission have been reported in studies of newly diagnosed cats treated with intensive long-acting insulin protocols and low carbohydrate diets, these protocols may not be suitable for all clients. Nearly 50% of cats with newly diagnosed diabetes achieved remission with this low-cost, moderate-intensity, insulin dosing protocol. As remission was significantly associated with survival time, discussing factors in treatment to optimise remission is important, but it is also important to offer clients a spectrum of options. No cats that started treatment in this study were euthanased because the owner did not wish to continue the diabetes treatment.


Assuntos
Doenças do Gato , Hipoglicemiantes , Insulina Glargina , Gatos , Animais , Doenças do Gato/tratamento farmacológico , Feminino , Insulina Glargina/uso terapêutico , Insulina Glargina/administração & dosagem , Masculino , Estudos Retrospectivos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Automonitorização da Glicemia/veterinária , Diabetes Mellitus/veterinária , Diabetes Mellitus/tratamento farmacológico , Glicemia/análise , Indução de Remissão , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-38459745

RESUMO

OBJECTIVES: To evaluate the feasibility of using the FreeStyle Libre (a continuous glucose monitoring system [CGMS]) for instantaneous continuous monitoring of interstitial glucose in adult horses and examine the applicability and accuracy of this system in horses submitted to combined glucose-insulin test (CGIT). DESIGN: Laboratory measurements and continuous glucose monitoring system (CGMS) readings were analyzed using a 2 × 2 factorial statistical model with repeated measures over time. This analysis assessed the effects of the test (factor 1), group (factor 2), and their interactions (test × group, test × time, and group × time). Pearson's correlation analysis was applied to blood glucose values. Mean comparisons were conducted using the t-test, and agreement between techniques was assessed via the Bland-Altman method, with a 95% confidence interval. SETTING: Field study on private horse farms in association with a veterinary school. ANIMALS: Ten healthy stallions were assigned to one of two groups based on their body condition scores (BCS). Group 1 (G1, n = 5) consisted of nonobese horses with a BCS of 5 or 6, while Group 2 (G2, n = 5) consisted of obese horses with a BCS of 7 or higher. INTERVENTIONS: A CGMS sensor was attached to the dorsolateral aspect of the proximal one third of each horse's neck. Laboratory blood glucose measurements and CGMS interstitial glucose readings were compared at different time points for up to 7 days after sensor fixation. Obese horses were also submitted to CGIT on Day 4. MEASUREMENTS AND MAIN RESULTS: A comparative analysis of glucose measurements obtained in G1 and G2 horses using the CGMS and enzymatic methods revealed significant group × time interactions (P < 0.001) and time effects (P < 0.001). No interactions were detected between group (P = 0.45), test (P = 0.62), group and test (P = 0.28), or time and test (P = 0.92). In G1 and G2, tests were significantly correlated (r = 0.84 and P = 0.00) at all time points (T0-T5). Agreement between the glucose values obtained using different methods was excellent despite a small time delay in CGMS detection of rapid changes in blood glucose. CONCLUSIONS: It was concluded that the CGMS can be used for indirect assessment of glycemic status (ie, based on interstitial glucose measurements) in nonobese and obese adult horses submitted to CGIT.


Assuntos
Glicemia , Doenças dos Cavalos , Cavalos , Animais , Masculino , Glicemia/análise , Insulina , Automonitorização da Glicemia/veterinária , 60431/veterinária , Glucose , Obesidade/veterinária
3.
Res Vet Sci ; 169: 105156, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38340380

RESUMO

Glycemic variability (GV) refers to swings in blood glucose levels and is an emerging measure of glycemic control in clinical practice. It is associated with micro- and macrovascular complications and poor clinical outcomes in diabetic humans. Although an integral part of patient assessment in human patients, it is to a large extent neglected in insulin-treated diabetic dogs. This prospective pilot study was performed to describe canine within-day GV in non-diabetic dogs with the aim to provide a basis for the interpretation of daily glucose profiles, and to promote GV as an accessible tool for future studies in veterinary medicine. Interstitial glucose concentrations of ten non-diabetic, non-obese beagles were continuously measured over a 48-h period using a flash glucose monitoring system. GV was assessed using the common indices MAGE (mean amplitude of glycemic excursion), GVP (Glycemic variability percentage) and CV (coefficient of variation). A total of 2260 sensor measurements were obtained, ranging from 3.7 mmol/L (67 mg/dL) to 8.5 mmol/L (153 mg/dL). Glucose profiles suggested a meal-dependent circadian rhythmicity with small but significant surges during the feeding periods. No differences in GV indices were observed between day and night periods (p > 0.05). The MAGE (mmol/L), GVP (%) and CV (%) were 0.86 (± 0.19), 7.37 (± 1.65), 6.72 (± 0.89) on day one, and 0.83 (± 0.18), 6.95 (± 1.52), 6.72 (± 1.53) on day two, respectively. The results of this study suggest that GV is low in non-diabetic dogs and that glucose concentrations are kept within narrow ranges.


Assuntos
Diabetes Mellitus Tipo 2 , Diabetes Mellitus , Doenças do Cão , Humanos , Animais , Cães , Glicemia , Automonitorização da Glicemia/veterinária , Estudos Prospectivos , Projetos Piloto , Diabetes Mellitus/veterinária , Diabetes Mellitus Tipo 2/veterinária
4.
J Am Vet Med Assoc ; 262(4): 1-5, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38190800

RESUMO

OBJECTIVE: The objective of this study was to evaluate the accuracy of a beta prototype version of a new portable blood glucose meter in feline patients. ANIMALS: 60 client-owned cats. METHODS: In this prospective study, 3-mL blood samples were collected from each cat and analyzed in triplicate using a beta prototype device (AlphaTRAK 3 [AT3]) and by a reference lab standard immediately after collection. Accuracy of the AT3 device was determined in accordance with the International Organization of Standardization (ISO) 15197:2013 criteria, including Bland-Altman plotting and consensus error grid analysis. A Passing-Bablok regression analysis was also performed. RESULTS: 96% of feline measurements fell within the ISO accuracy threshold, and 100% of measurements fell within zones A and B of the consensus error grid, meeting the ISO accuracy requirements. There was no significant bias in the data according to the Bland-Altman analysis. Within the full range of glucose concentrations (20 to 750 mg/dL) the correlation coefficient between the AT3 and the reference lab standard was 0.99. There was no significant constant or proportional bias present in the data. CLINICAL RELEVANCE: The AT3 device met the ISO requirements and is accurate for measurement of blood glucose concentrations in cats.


Assuntos
Automonitorização da Glicemia , Glicemia , Humanos , Gatos , Animais , Glicemia/análise , Estudos Prospectivos , Automonitorização da Glicemia/veterinária , Análise de Regressão , Reprodutibilidade dos Testes
5.
Can J Vet Res ; 87(4): 260-264, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37790268

RESUMO

Interstitial glucose monitoring systems are commonly being used in diabetic dogs. The aim of this study was to document the incidence of complications associated with the use of a flash glucose monitoring system (FGMS) in dogs. Medical records of dogs that had placement of a 14-day FGMS during a 1-year period were reviewed. Data retrieved included the number of days the sensor remained attached and functional, sensor detachment, sensor failure prior to the end of the 14-day monitoring period, and dermatologic changes at the sensor site. Descriptive statistics were used to characterize the data. Thirty-four dogs had FGMSs placed. Most [32/34 (94%)] sensors were placed over the dorsolateral aspect of the thorax caudal to the scapula. Twenty-four sensors (71%) remained attached for the full 14 days. Incidence of complications associated with FGMS use was 13/34 (38%). The most frequent complication was mild dermatologic changes at the sensor site [6/34 (18%)]. Erythema and crusting at the attachment site were common and could be related to contact dermatitis, hypersensitivity, or skin preparation prior to placement. Flash glucose monitoring systems are safe in dogs, although there are some potential complications that should be discussed with dog owners.


Les systèmes de surveillance du glucose interstitiel sont couramment utilisés chez les chiens diabétiques. Le but de cette étude était de documenter l'incidence des complications associées à l'utilisation d'un système de surveillance flash du glucose (FGMS) chez le chien. Les dossiers médicaux des chiens qui ont eu la mise en place pendant 14 jours d'un FGMS au cours d'une période d'un an ont été examinés. Les données récupérées comprenaient le nombre de jours pendant lesquels le capteur est resté attaché et fonctionnel, le détachement du capteur, la défaillance du capteur avant la fin de la période de surveillance de 14 jours et les changements dermatologiques au site du capteur. Des statistiques descriptives ont été utilisées pour caractériser les données. Trente-quatre chiens ont eu des FGMS placés. La plupart [32/34 (94 %)] des capteurs ont été placés sur la face dorsolatérale du thorax caudal à l'omoplate. Vingt-quatre capteurs (71 %) sont restés attachés pendant les 14 jours complets. L'incidence des complications associées à l'utilisation du FGMS était de 13/34 (38 %). La complication la plus fréquente était de légers changements dermatologiques au niveau du site du capteur [6/34 (18 %)]. L'érythème et la formation de croûtes au site de fixation étaient courants et pouvaient être liés à une dermatite de contact, à une hypersensibilité ou à la préparation cutanée avant la mise en place. Les systèmes de surveillance flash de la glycémie sont sans danger pour les chiens, bien qu'il existe certaines complications potentielles qui devraient être discutées avec les propriétaires de chiens.(Traduit par Docteur Serge Messier).


Assuntos
Diabetes Mellitus , Doenças do Cão , Cães , Animais , Glucose , Automonitorização da Glicemia/veterinária , Glicemia , Diabetes Mellitus/veterinária , Monitorização Fisiológica/veterinária , Monitorização Fisiológica/métodos
6.
J Vet Diagn Invest ; 35(6): 710-720, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37608786

RESUMO

Veterinary glucometers should be correctly coded for the patient species; however, coding errors occur in clinical settings and the impact of such errors has not been characterized. We compared glucose concentrations in 127 canine and 37 feline samples using both canine and feline settings on a veterinary glucometer (AlphaTrak; Zoetis). All samples were measured first on the canine setting and then measured using the feline setting. Glucose concentration was also measured using a central laboratory biochemical analyzer (Cobas c311; Roche). Three data comparisons for each species were investigated: incorrectly coded glucometer vs. correctly coded glucometer, correctly coded glucometer vs. Cobas c311, and incorrectly coded glucometer vs. Cobas c311. For each comparison, the following analyses were conducted: Spearman rank correlation coefficient, Bland-Altman difference plot analysis, mountain plot analysis, and Deming regression. For clinical context, Clarke error grids were constructed. There was high positive correlation for all comparisons with both species. For all comparisons, mean difference was low (-0.7 to 0.5 mmol/L for canine samples, 1.0-2.0 mmol/L for feline samples). Incorrect glucometer coding resulted in proportional bias for canine samples and positive constant bias for feline samples, and individual differences could be large (-4.44 mmol/L for one dog, 6.16 mmol/L for one cat). Although the glucometer should be used per the manufacturer's recommendation, coding errors are unlikely to have severe adverse clinical consequences for most patients based on error grid analysis.


Assuntos
Doenças do Gato , Doenças do Cão , Animais , Gatos , Cães , Glicemia/análise , Doenças do Gato/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Doenças do Cão/diagnóstico , Automonitorização da Glicemia/veterinária
7.
J Vet Intern Med ; 37(5): 1703-1709, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37534946

RESUMO

BACKGROUND: Continuous glucose monitoring systems have been validated for eu- and hyperglycemic cats. The FreeStyle Libre 2 (FSL2) is sufficiently accurate in people during hypoglycemia to guide critical treatment decisions without confirmation of blood glucose concentration (BG). OBJECTIVES: Assess FSL2 accuracy in cats with hypoglycemia. ANIMALS: Nine healthy, purpose-bred cats. METHODS: Hyperinsulinemic-hypoglycemic clamps were performed by IV infusion of regular insulin (constant rate) and glucose (variable rate). Interstitial glucose concentration (IG), measured by FSL2, was compared to BG measured by AlphaTrak2. Data were analyzed for all paired measurements (n = 364) and separately during stable BG (≤1 mg/dL/min change over 10 minutes). Pearson's r test, Bland-Altman test, and Parkes Error Grid analysis respectively were used to determine correlation, bias, and clinical accuracy (P < .05 considered significant). RESULTS: Overall, BG and IG correlated strongly (r = 0.83, P < .0001) in stable glycemia and moderately at all rates of change (r = 0.69, P < .0001). Interstitial glucose concentration underestimated BG in euglycemia, but the BG-IG difference was progressively smaller as BG decreased (12.9 ± 12.2, 8.8 ± 11.2, -3.2 ± 7.4, and -7.8 ± 5.2 mg/dL in the ranges of 80-120 [n = 64], 60-79 [n = 29], 50-59 [n = 71], and 29-49 mg/dL [n = 53], respectively). CONCLUSIONS: Although IG underestimates BG throughout most of the hypo-euglycemic range, IG generally overestimates BG in marked hypoglycemia (<60 mg/dL). It is therefore imperative to evaluate FSL2 results in this critical range with caution.


Assuntos
Doenças do Gato , Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Gatos , Animais , Glicemia/análise , Automonitorização da Glicemia/veterinária , Diabetes Mellitus Tipo 1/veterinária , Glucose , Hipoglicemia/veterinária , Doenças do Gato/diagnóstico
8.
J Am Vet Med Assoc ; 261(10): 1475-1408, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37406997

RESUMO

OBJECTIVE: To compare the performance of an interstitial glucose monitor (IGM) versus a portable blood glucose monitor (PBGM) in sick juvenile dogs in a veterinary ICU. ANIMALS: 16 client-owned dogs admitted to the university teaching hospital under 1 year of age with systemic illness. PROCEDURES: Paired interstitial and blood glucose samples were collected. A third glucose measurement with a reference method was obtained when IGM and PBGM values were clinically disparate. Analytical accuracy was measured by Pearson correlation and agreement statistics, including mean absolute relative difference (MARD), bias, and 95% limits of agreement. The Parkes consensus error grid analysis was performed to assess clinical accuracy. RESULTS: 159 paired glucose measurements were available for analysis. Comparison of IGM readings to PBGM measurements resulted in an MARD of 15.4% and bias of -2.6%, with the 95% limits of agreement ranging from -42.5% to 37.4%. Positive correlation between IGM and PBGM (Pearson r = 0.65) was found. On consensus error grid analysis, 100% of the pairs fell into clinically acceptable zones (74.2% in zone A, and 25.8% in zone B). When disparate IGM and PBGM readings were compared to a laboratory reference standard (n = 13), both methods resulted in high MARD and wide limits of agreement. CLINICAL RELEVANCE: The IGM provides clinically acceptable glucose measurements compared to PBGM to monitor glucose levels in juvenile dogs in a clinical setting. Further clinical studies with a larger sample size, particularly in the hypoglycemic range, are needed to assess IGM performance in the lower glucose range.


Assuntos
Automonitorização da Glicemia , Glicemia , Cães , Animais , Glicemia/análise , Automonitorização da Glicemia/veterinária , Imunoglobulina M , Reprodutibilidade dos Testes
9.
J Anim Sci ; 1012023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-37279537

RESUMO

Obesity has become a major health issue in dogs. Obesity in dogs increases the risk of many chronic diseases and chronic low-grade inflammation. The objective of this study was to determine the effect of a therapeutic weight loss (TWL) diet on weight loss and metabolic health in overweight and obese dogs. Thirty overweight and obese dogs were randomized into two groups with 15 dogs per group based on key baseline (BSL) parameters and allotted to either a control or TWL diet for 6 mo. At the start of the study, the control group had six females and nine males with mean age of 9.12 ±â€…0.48 (mean ±â€…SEM) yr; there were seven females and eight males with mean age of 9.73 ±â€…0.63 yr in the TWL group. The control group and the TWL group had comparable body weight (34.78 ±â€…0.76 and 34.63 ±â€…0.86 kg, respectively), % body fat (BF; 39.77 ±â€…1.18 and 39.89 ±â€…0.93, respectively), and body condition score (BCS; 7.80 ±â€…0.14 and 7.67 ±â€…0.16 on a 9-point BCS scale, respectively). The control (CTRL) diet was formulated based on the macronutrient ratio of a commercial metabolic diet, and the TWL diet was enriched with dietary protein, fish oil, and soy germ meal. Both diets were fortified with essential nutrients to account for caloric restriction during weight loss. Dogs were fed with 25% less than BSL maintenance energy requirement (MER) for the first 4 mo and if they did not reach a BCS of 5, they were fed 40% less than BSL MER for the last 2 mo. Body composition was determined by dual-energy x-ray absorptiometry. Postprandial glucose profiles were determined by continuous glucose monitoring devices. Serum samples were collected for analyses of blood parameters, hormones, and cytokines. All data were analyzed using SAS 9.3, with significance being P < 0.05. At the end of the study, the control group and the TWL group had comparable weight loss (-5.77 ±â€…0.31 and -6.14 ±â€…0.32 kg, respectively; P = 0.4080). But the TWL group lost significantly (P = 0.034) more BF (-13.27 ±â€…1.28%) than the control group (-9.90 ±â€…1.23%). In addition, the TWL diet completely prevented loss of lean body mass (LBM) in dogs compared with BSL. Dogs fed with the TWL diet had significantly lower fasting serum cholesterol, triglycerides, insulin, leptin, mean postprandial interstitial glucose, and pro-inflammatory cytokines compared with dogs fed with the CTRL diet. In summary, the TWL diet prevented loss of LBM, promoted weight loss and metabolic health, and reduced pro-inflammatory cytokines and chemokines in overweight and obese dogs during weight loss.


Obesity has become a major health issue in dogs and increases the risk of many chronic diseases and chronic low-grade inflammation. The objective of this study was to determine the effect of a therapeutic weight loss (TWL) diet on weight loss and metabolic health in overweight and obese dogs. Thirty overweight and obese dogs were randomized into two groups with 15 dogs per group and assigned to either a control (CTRL) diet or TWL diet for a 6 mo weight loss study. Changes in body composition were determined every 2 mo. Blood samples were collected to measure changes in lipid profiles, hormones, cytokines, and chemokines. Postprandial glucose profiles were determined by a continuous glucose monitoring system. The results of the study showed that the TWL diet completely prevented loss of lean body mass (LBM) in dogs compared with baseline. Dogs fed with the TWL diet had significantly lower fasting serum cholesterol, triglycerides, insulin, leptin, mean postprandial glucose, and pro-inflammatory cytokines compared with dogs fed with the CTRL diet. In summary, the TWL diet prevented loss of LBM, promoted weight loss and metabolic health, and reduced pro-inflammatory cytokines in overweight and obese dogs during weight loss.


Assuntos
Dieta Redutora , Doenças do Cão , Masculino , Feminino , Cães , Animais , Dieta Redutora/veterinária , Sobrepeso/veterinária , Automonitorização da Glicemia/veterinária , Glicemia/metabolismo , Obesidade/veterinária , Redução de Peso , Composição Corporal , Glucose , Citocinas/metabolismo
10.
Am J Vet Res ; 84(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37080253

RESUMO

OBJECTIVE: Flash glucose monitoring systems (FGMS) are frequently used for interstitial glucose monitoring in dogs with diabetes mellitus and are typically placed between the scapulae. We aimed to evaluate the variability between glucose measurements from FGMS placed in 2 locations (between the scapulae and over the hip) in non-diabetic dogs during rapidly induced hypoglycemia. ANIMALS: 24 apparently healthy colony dogs that were subjects in a teaching laboratory. PROCEDURES: Prospective interventional study. FGMS sensors (FreeStyle Libre 14-day system) were placed between the scapulae and over the hip of all dogs. Regular insulin was administered (0.3 u/kg IV) and subsequent hypoglycemia was corrected. Before insulin administration and every 10 minutes over 90 minutes, interstitial glucose was recorded from both locations, and blood glucose was measured with a point-of-care blood glucose monitor (AlphaTRAK 2). RESULTS: There was a constant bias of 5.6 mg/dL (95% limits of agreement: -26.3 to 37.5 mg/dL) between locations, but the proportional bias was not apparent. There was a correlation between FGMS locations (r = 0.731, P = < .001). Sensor site B was clinically accurate with 100% of paired samples within Parkes error grid zones A (83%) and B (17%) but did not meet the criteria for analytical accuracy. CLINICAL RELEVANCE: In this model of induced hypoglycemia in healthy dogs, variation between measurements from FGMS locations was unlikely to have affected the clinical outcome. Placement of FGMS over the hip may be an acceptable alternative to placement between the scapulae, but the utility in hyperglycemic dogs is unknown.


Assuntos
Doenças do Cão , Hipoglicemia , Cães , Animais , Hipoglicemiantes , Glicemia , Glucose , Automonitorização da Glicemia/veterinária , Estudos Prospectivos , Hipoglicemia/veterinária , Insulina/uso terapêutico
11.
Vet Clin North Am Small Anim Pract ; 53(3): 591-613, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36854635

RESUMO

In recent years, glucose monitoring has been revolutionized by the development of continuous glucose monitoring systems (CGMS), which are wearable non/minimally invasive devices that measure glucose concentration almost continuously for several consecutive d/wk. The Abbott FreeStyle Libre is the CGMS used most commonly. It has adequate clinical accuracy both in dogs and cats, even though the accuracy is lower in the hypoglycemic range. It allows an accurate identification of glycemic excursions occurring throughout the day as well as of glucose variations during consecutive days, enabling the clinician to make a more informed decision about the insulin dose and frequency of administration.


Assuntos
Doenças do Gato , Doenças do Cão , Gatos , Cães , Animais , Glicemia , Automonitorização da Glicemia/veterinária , Doenças do Gato/diagnóstico , Doenças do Cão/diagnóstico , Tecnologia
12.
Vet Rec ; 192(2): e2236, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36180819

RESUMO

BACKGROUND: Serum fructosamine (sFA) is used to assess glycaemic control in dogs with diabetes mellitus (DM). Nevertheless, its interpretation is hindered by several limitations. METHODS: This retrospective study evaluates the long-term diagnostic performance of sFA for monitoring clinical control of DM. sFA, bodyweight, appetite, presence of polyuria/polydipsia and clinical scores (CS; well-controlled DM, CS-0; uncontrolled DM, CS-1) were recorded. RESULTS: The study included 75 dogs (321 visits; median 3 visits/dog; range 1-19). Mean sFA was higher (p < 0.001) on visits with CS-1 (584 µmol/L; 95% confidence interval [95% CI] 561-608) than on visits with CS-0 (506 µmol/L; 95% CI 484-528). Increases in sFA increased   the odds ratio for CS-1 (1.37; 95% CI 1.24-1.52, p < 0.001). sFA was moderately predictive of the CS (area under receiver operating characteristic curve = 0.75; 95% CI 0.70-0.80; p < 0.0001), with a 486 µmol/L cutoff yielding 80% sensitivity and 59% specificity. Mean sFA was lower (p = 0.005) when hypoglycaemic episodes were suspected (496 µmol/L; 95% CI 450-541) than in their absence (572 µmol/L; 95% CI 548-596). sFA is moderately accurate for classifying CS in diabetic dogs. Decreasing sFA over follow-ups indicates improved CS but might suggest occurrence of hypoglycaemic episodes. LIMITATIONS: Retrospective design, variable treatments and comorbidities are limitations of this study. CONCLUSION: sFA has a moderate clinical utility in the long-term monitoring of diabetic dogs, but may serve as a first-line, accessible diagnostic tool. Discordant CS and sFA evaluation, or decreased sFA, warrants additional monitoring (i.e., continuous glucose monitoring).


Assuntos
Diabetes Mellitus , Doenças do Cão , Hipoglicemia , Cães , Animais , Frutosamina , Estudos Retrospectivos , Automonitorização da Glicemia/veterinária , Glicemia , Diabetes Mellitus/veterinária , Diabetes Mellitus/diagnóstico , Hipoglicemia/veterinária , Hipoglicemiantes , Doenças do Cão/diagnóstico
13.
J Am Vet Med Assoc ; 261(2): 229-236, 2022 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-36288205

RESUMO

OBJECTIVE: To evaluate whether intraoperative detection of rising levels of blood glucose could improve the completeness of resection of insulin-secreting tumor tissue and whether this improves long-term outcomes. ANIMALS: 11 client-owned dogs diagnosed with insulinoma. PROCEDURES: Retrospective review of medical records of dogs undergoing partial pancreatectomy as treatment for insulinoma. A blood glucose reading was obtained at induction, following removal of the pancreatic mass and/or after each suspected metastatic lesion until blood glucose had normalized. Disease-free interval and survival time were measures of outcome. RESULTS: A positive increase in blood glucose was detected in all cases, with a mean rise of 6.35 ± 4.5 mmol/L. Mean follow-up was 611 days, mean disease-free interval was 382 days, and median survival time was 762 days. Tumor stage was not associated with outcome. Three cases underwent a second surgery (metastasectomy), achieving further prolongation of disease-free survival. CLINICAL RELEVANCE: A sustained increase in intraoperative blood glucose provided the surgeon with confidence of more complete resection of insulinoma tissue and resulted in improved outcomes in all cases included in this study. Subsequent metastasectomy of recurrent insulinoma lesions also provided good outcomes. Intraoperative monitoring of blood glucose during surgical treatment of insulinoma resulted in the surgeon continuing to explore and resect abnormal tissue until an increase of glycemia was observed. This was shown to provide the surgeon with more confidence of resection of all active insulinoma tissue and improved clinical outcomes.


Assuntos
Doenças do Cão , Insulinoma , Neoplasias Pancreáticas , Cães , Animais , Insulinoma/diagnóstico , Insulinoma/cirurgia , Insulinoma/veterinária , Glicemia , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/veterinária , Automonitorização da Glicemia/veterinária , Insulina , Doenças do Cão/diagnóstico , Doenças do Cão/cirurgia
14.
J Vet Diagn Invest ; 34(5): 789-795, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35993265

RESUMO

Glucose and trehalose are the main energy sources used by honeybees (Apis mellifera) for daily activities. However, there is no validated point-of-care method to reliably measure both sugars. We performed an analytical validation of a portable human glucometer (Accu-Chek; Roche) for glucose measurement in honeybee hemolymph compared to a reference method (GluCH, UniCel DxC 600; Beckman Coulter). We used 30 pooled hemolymph samples collected from the antennae of anesthetized honeybees and diluted 1:4 in 0.9% saline. We evaluated dilution linearity, spike recovery, and inter- and intra-assay imprecision. Glucose concentration was measured over time (2 h, 4 h, 8 h, 12 h, 1 d, 2 d, 3 d, 7 d, 21 d, 28 d) at various storage temperature (25°C, 4°C, -20°C, -80°C). The trehalose concentration was measured indirectly by trehalase hydrolyzation. Glucose concentrations measured by both instruments had a strong correlation (0.985, p < 0.0001) and a bias of -7.33 mmol/L (±1.96SD: 13.70 to -28.36), with linear agreement at <20 mmol/L (physiologic value: 100 mmol/L). The accuracy of the glucometer decreased at >20 mmol/L. Recovery of 115-130% of diluted spikes indicated good specificity. Inter- and intra-assay imprecision were 2.50% and 2.21%, respectively. Glucose concentrations fluctuated in stored samples dependent on time and temperature; however, glucose concentrations were constant with storage at -80°C for ≥28 d. The Accu-Chek glucometer is an adequate instrument to measure honeybee glucose concentration in hemolymph diluted with 0.9% NaCl, with good accuracy and precision at <20 mmol/L. Hemolymph storage at -80°C is suitable for long-term conservation of glucose.


Assuntos
Glicemia , Hemolinfa , Animais , Abelhas , Automonitorização da Glicemia/métodos , Automonitorização da Glicemia/veterinária , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Trealose
15.
Rev. bras. ciênc. vet ; 29(3): 125-129, jul./set. 2022. il.
Artigo em Espanhol | LILACS, VETINDEX | ID: biblio-1411217

RESUMO

La medición de glucosa en caninos es un procedimiento habitual en la clínica diaria, actualmente este valor se puede obtener mediante dispositivos portátiles y pruebas laboratoriales. Se realizó esta investigación con el fin de aportar mayor conocimiento sobre la importancia de la medición de glucosa, ya que en los últimos años ha perdido valor entre las pruebas hematológicas a considerar debido a que solo se relaciona con determinadas patologías como la diabetes u otras enfermedades metabólicas. El presente trabajo tiene como objetivo comparar los valores de glucosa en caninos obtenidos mediante un glucómetro portátil de uso humano (Accu-chek® Active, Roche Diagnostic, Mannheim, Alemania); veterinario (aLcose® Vet Glu, jjPlus Corporation, New Taipei, Taiwán) y la prueba estándar de laboratorio, esto nos indicará la fiabilidad de los resultados obtenidos mediante estos métodos. Se realizó la toma de muestras de sangre de 50 caninos clínicamente sanos, de los cuales se obtuvo el resultado de glucemia mediante estos tres métodos. Los resultados de nuestra investigación evidenciaron que las tres formas de evaluación de la glucosa sanguínea en perros brindaban resultados estadísticamente diferentes (p < 0.05). Se obtuvo valores de glucosa diferentes entre los tres métodos de medición, teniendo como promedios finales 84.14 mg/dL, 101.12 mg/dL y 91.12 mg/dL correspondientes al glucómetro portátil de uso humano, veterinario y a la prueba estándar de laboratorio respectivamente. En conclusión, los glucómetros portátiles de uso humano subestiman los valores reales de glucosa, mientras que los de uso veterinario lo sobreestiman, comparados con la prueba estándar de laboratorio.


A medição de glicose nos cães é um procedimento habitual realizado no atendimento clínico. Atualmente este valor pode ser obtido por meio de dispositivos portáteis e testes laboratoriais. Esta pesquisa foi realizada com a finalidade de destacar a importância da medição de glicose, visto que nos últimos anos esta avaliação não tem sido muito valorada entre os testes hematológicos, sendo considerada relevante apenas em relação a patologias como a diabetes e outras doenças metabólicas. O presente estudo teve como objetivo comparar os valores de glicose em cães obtidos com glicômetro portátil de uso humano; veterinário e o teste padrão de laboratório. Esta comparação poderá indicar a confiabilidade dos resultados obtidos mediante os métodos avaliados. Foi realizada a amostragem do sangue de 50 caninos clinicamente sadios os quais foram submetidos a avaliação de glicose mediante os três métodos. Os resultados de nossa investigação evidenciaram que as três formas de avaliação da glicose sanguínea têm resultados estatisticamente diferentes (p < 0,05). Os valores de glicose tiveram medias finais de 84,14 mg/dL, 101,12 mg/dL e 91,12 mg/dL para o glicômetro portátil de uso humano (Accu-chek® Active, Roche Diagnostic, Mannheim, Alemanha), veterinário (aLcose® Vet Glu, jjPlus Corporation, Nova Taipei, Taiwan) e o teste padrão de laboratório, respectivamente. Ao concluir, os glicômetros portáteis de uso humano subestimam os valores reais de glicose e os de uso veterinário os superestimam quando comparados com o teste padrão de laboratório.


The measurement of glucose in canines is a common procedure in daily clinical practice. Currently this value can be obtained by use of portable devices and laboratory tests. This research was carried out in order to provide more knowledge about the importance of glucose measurement, since in recent years it has lost value among the hematological tests to be considered because it is only related to certain pathologies such as diabetes or other metabolic diseases. The present study aimed to compare the glucose values in dogs obtained with a portable glucometer for human use, veterinarian use, and the standard laboratory test. This comparison may indicate the reliability of the results obtained through the evaluated methods. A blood sampling of 50 clinically healthy canines was taken and submitted to glucose evaluation using the three methods. Our investigation showed that the three ways of assessing blood glucose have statistically different results (p < 0.05). Glucose values had final averages of 84.14 mg/dL, 101.12 mg/dL, and 91.12 mg/dL for the portable glucometer for human use (Accu-chek® Active, Roche Diagnostic, Mannheim, Germany), veterinary (aLcose® Vet Glu, jjPlus Corporation, New Taipei, Taiwan) and the standard laboratory test, respectively. In conclusion, portable glucometers for human use underestimate the glucose values, and those for veterinary use overestimate them compared to the standard laboratory test.


Assuntos
Animais , Cães , Análise Química do Sangue/veterinária , Glicemia/análise , Automonitorização da Glicemia/veterinária , Cães/sangue , Glucose/análise , Teste de Tolerância a Glucose/veterinária
16.
Domest Anim Endocrinol ; 81: 106732, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35689953

RESUMO

Capromorelin is a ghrelin-receptor agonist widely used as an appetite stimulant in dogs. Capromorelin disrupts glucose homeostasis in cats but information regarding its effects on canine glucose homeostasis is lacking. The study objective was to evaluate the effect of capromorelin on glucose homeostatic mechanisms in healthy dogs. Eight clinically healthy client-owned adult dogs were enrolled in this prospective, cross-over, placebo-controlled study. Dogs were randomized to receive capromorelin (Entyce, 3 mg/kg) or placebo, q24h for 3 d. A wk later, treatments were crossed over. Interstitial glucose (IG) concentrations were measured using a flash glucose monitoring system throughout. On d 1 of each treatment, blood glucose (BG), insulin, glucagon, glucose-dependent insulinotropic peptide (GIP), and glucagon-like peptide-1 (GLP-1) concentrations were measured before drug administration, then before and 30-120 min after feeding a glucose-rich diet (Ensure Plus, 21 kcal/kg). Data were analyzed as a 2-period crossover design using generalized least squares estimation. Capromorelin administration increased mean 48 h IG by10% and mean BG by 20% at 90 and 120 min post-prandially (P < 0.0001). Post-prandially, there was a time-by-treatment effect for insulin (P = 0.03) and GIP (P = 0.0002) because capromorelin doubled geometric mean insulin concentrations at 120 min and increased geometric mean GIP concentrations more rapidly than after placebo. There were no differences in glucagon or GLP-1 concentrations between treatment groups. The increase in post-prandial blood glucose was not the result of overt suppression of incretin hormone secretion. There was also no suppressive effect of capromorelin on insulin.


Assuntos
Glicemia , Glucagon , Animais , Automonitorização da Glicemia/veterinária , Gatos , Cães , Polipeptídeo Inibidor Gástrico , Peptídeo 1 Semelhante ao Glucagon , Glucose , Controle Glicêmico/veterinária , Insulina , Piperidinas , Estudos Prospectivos , Pirazóis
17.
J Feline Med Surg ; 24(8): e223-e231, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35762266

RESUMO

OBJECTIVES: Home blood glucose monitoring using a portable blood glucose meter is important in the management of feline diabetes mellitus, but taking blood samples may be stressful for owners and cats. A flash glucose monitoring system measuring interstitial glucose, such as the FreeStyle Libre, overcomes some of these drawbacks. The aim of this study was to evaluate the practical use and analytical and clinical accuracy of the FreeStyle Libre in 41 client-owned diabetic cats. METHODS: In this prospective study, interstitial glucose concentrations were measured with the FreeStyle Libre and compared with blood glucose concentrations measured with a portable blood glucose meter (AlphaTRAK) on days 1, 7 or 8 and 14 after application of the device. Cat behaviour during application, location, skin reaction at the attachment site and owner satisfaction were assessed. Accuracy was determined by fulfilment of ISO 15197:2013 criteria, including Bland-Altman plotting and error grid analysis. RESULTS: Placing the device was easy, with 70% of cats showing no reaction. Most sensors were placed on the thoracic wall. Skin reactions at the attachment site were not present or mild in almost all cats. Owners were very satisfied with the use of the FreeStyle Libre. Median functional life of the sensor was 10 days (range 1-14). Good correlation was found between interstitial and blood glucose measurements (rho[r] = 0.88, P <0.0001). Fifty-three percent of interstitial glucose concentrations were within a maximum deviation of 15% from blood glucose concentrations and 92.7% were within the safe risk zones 0 and 1 of the surveillance error grid. CONCLUSIONS AND RELEVANCE: The flash glucose monitoring system was easy to use and owners of diabetic cats were satisfied with its use. Although the device did not completely fulfil ISO requirements, it is sufficiently accurate for glucose monitoring in diabetic cats.


Assuntos
Doenças do Gato , Diabetes Mellitus , Animais , Glicemia/análise , Automonitorização da Glicemia/veterinária , Doenças do Gato/diagnóstico , Gatos , Diabetes Mellitus/veterinária , Glucose , Estudos Prospectivos
18.
J Vet Intern Med ; 36(4): 1211-1219, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35621084

RESUMO

BACKGROUND: For the treatment of diabetes mellitus (DM) in dogs, novel insulins with decreased injection frequency while maintaining safety and efficacy are desirable. Insulin fused with immunoglobulin-fragment-crystallizable (Fc) has an ultra-long plasma half-life because it recycles through cells, protected from proteolysis. HYPOTHESIS: Glycemic control can be achieved in diabetic dogs with a recombinant fusion protein of a synthetic insulin and canine Fc (AKS-218d) administered subcutaneously once-weekly. ANIMALS: Five client-owned dogs with naturally occurring DM. METHODS: Prospective clinical trial in dogs with DM that were recruited from the UC Davis Veterinary Teaching Hospital and local veterinary clinics. Dogs previously controlled using intermediate-acting insulin q12h were transitioned to once-weekly injections of a preliminary construct identified as AKS-218d. The dose of AKS-218d was titrated weekly for 8 weeks based on clinical response and continuous interstitial glucose monitoring. Clinical signs, body weight, serum fructosamine concentrations, and mean interstitial glucose concentrations (IG) over the preceding week were compared between baseline (before AKS-218d) and during the last week of treatment. Data were compared using nonparametric paired tests. RESULTS: Once-weekly AKS-218d, compared to baseline twice-daily insulin therapy, resulted in no significant changes in clinical signs, median (range) body weight (+0.4 kg [-0.5-1.1]; P = .6), fructosamine concentration (-75 mmol/L [-215 to +126]; P = .4), or mean IG (+81 mg/dL [-282 to +144]; P = .8). No adverse reactions were reported. CONCLUSION: Control of clinical signs, body weight, and maintenance of glycemia was achieved with this once-weekly novel insulin construct in 4 of 5 dogs.


Assuntos
Diabetes Mellitus Tipo 2 , Diabetes Mellitus , Doenças do Cão , Animais , Glicemia/metabolismo , Automonitorização da Glicemia/veterinária , Peso Corporal , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/veterinária , Diabetes Mellitus Tipo 2/veterinária , Cães , Frutosamina , Hospitais Veterinários , Hospitais de Ensino , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Insulina Glargina/efeitos adversos , Estudos Prospectivos
19.
Am J Vet Res ; 83(3): 222-228, 2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-35038307

RESUMO

OBJECTIVE: To determine the accuracy of 2 interstitial glucose-monitoring systems (GMSs) for use in horses compared with a point-of-care (POC) glucometer and standard laboratory enzymatic chemistry method (CHEM). ANIMALS: 8 clinically normal adult horses. PROCEDURES: One of each GMS device (Dexcom G6 and Freestyle Libre 14-day) was placed on each horse, and blood glucose concentration was measured via POC and CHEM at 33 time points and compared with simultaneous GMS readings. An oral glucose absorption test (OGAT) was performed on day 2, and glucose concentrations were measured and compared. RESULTS: Glucose concentrations were significantly correlated with one another between all devices on days 1 to 5. Acceptable agreement was observed between Dexcom G6 and Freestyle Libre 14-day when compared with CHEM on days 1, 3, 4, and 5 with a combined mean bias of 10.45 mg/dL and 1.53 mg/dL, respectively. During dextrose-induced hyperglycemia on day 2, mean bias values for Dexcom G6 (10.49 mg/dL) and FreeStyle Libre 14-day (0.34 mg/dL) showed good agreement with CHEM. CLINICAL RELEVANCE: Serial blood glucose measurements are used to diagnose or monitor a variety of conditions in equine medicine; advances in near-continuous interstitial glucose monitoring allow for minimally invasive glucose assessment, thereby reducing stress and discomfort to patients. Data from this study support the use of the Dexcom G6 and Freestyle Libre 14-day interstitial glucose-monitoring systems to estimate blood glucose concentrations in horses.


Assuntos
Automonitorização da Glicemia , Glicemia , Animais , Automonitorização da Glicemia/veterinária , Eletrocardiografia , Cavalos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/veterinária , Sistemas Automatizados de Assistência Junto ao Leito
20.
Vet Rec ; 190(2): e244, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33870504

RESUMO

BACKGROUND: Although fructosamine is a commonly used surrogate marker to assess glycaemic control in diabetic dogs, its diagnostic accuracy has been questioned. The main objective of this study was to evaluate the reliability of fructosamine measurements to diagnose well and poorly controlled diabetes mellitus (DM), using continuous glucose monitoring as a gold standard. METHODS: Twenty-four dogs with treated DM and continuous glucose monitoring for mean (±SD) 13.1 (±1.7) days were retrospectively analysed. Two assessment strategies were applied to categorize glycaemic control, and fructosamine concentrations were determined shortly after sensor cessation using a colorimetric assay. RESULTS: Correlations of individual fructosamine concentrations with mean glucose as well as percentage of measurements > 15 mmol/L were not significant (p = 0.372, p = 0.129). Fructosamine did not differ between dogs with and without hypoglycaemic episodes (p = 0.64). Receiver operating characteristic analysis for fructosamine to diagnose either good or poor glycaemic control revealed AUC values of 0.71 (p = 0.025) indicating moderate accuracy, and 0.7 (p = 0.135) indicating AUC is non-discriminatory, respectively. The respective positive likelihood ratios for the optimal cutoffs to identify good (<396 µmol/L) and poor control (>449 µmol/L) were three. CONCLUSIONS: Fructosamine measurement is an imperfect surrogate marker for classifying glycaemic control in diabetic dogs and can only complement serial glucose measurements.


Assuntos
Diabetes Mellitus , Doenças do Cão , Animais , Biomarcadores , Glicemia , Automonitorização da Glicemia/veterinária , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/veterinária , Doenças do Cão/diagnóstico , Cães , Frutosamina , Hemoglobinas Glicadas/análise , Controle Glicêmico/veterinária , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...